The Windows version of the VictronConnect app does not support Bluetooth. Always verify the battery polarity before reconnecting the battery wires to the solar charger. It can occur when a battery is attached to the unit using a contactor. If you are doing a moderate sized DIY solar setup, 2000W or less, you have to get an Epever Tracer. There was a problem completing your request. In some circumstances, these items may be eligible for a refund or a replacement (for example, if you receive the wrong item due to an Amazon AU error or if the item is faulty). The controller is operational up to 60C, with a full rated output up to 40C. Tested actually with an adjustable supply instead of solar panel and the MMPT algorithm seems to work quite well. At the same time, the cell chip cracking problem continues to expand under mechanical load, which may lead to open circuit failure, and can also lead to a hot spot effect. Reviewed in the United States on June 12, 2021. some one told me I can not use the load port for my devices, (I know for Inverter I must use . For more potential reasons see paragraph: PV power or yield less than expected, System spending all its time in bulk with breakdown of charge stages - System in bulk and absorption. 5. Tap on the category links below for the associated return window and exceptions (if any) for returns. Check the total maximum power (Pmax) for each day. 1. If the link is clicked, an explanation will appear as to why the charger is off. This should be at the battery. For more information on system grounding, see chapter 7.7: "System grounding" in the Wiring Unlimited book. Compatible Product: VictronConnect charger enable/disable setting. Check if all cable lugs or cable terminals have been crimped correctly. Once the battery is full the solar charger will stop charging or will greatly reduce the charge current. No, the Solar Charge controller will automatically detect the battery voltage and if the battery dead, the charging process wont working, we recommend use a Individual Battery Charge to Fix and Restore the Dead Battery before reconnect it to solar system. For $200 it has amazing functionality. If a GX device is connected to the controller and the GX device is connected to Victron Remote Monitoring (VRM), errors will be sent to the VRM site as well as displayed on the GX device. These products are outstanding and provide very impressive performance. Please try again. This is certainly enough head room for the SCC to start charging so I am not surprised it worked. Check the VictronConnect app to make sure the charger has been enabled. This error will auto-reset. A system which never reaches the float stage could have the following issues: A problem with the array causing it to have a reduced power output. Compatible Products: Tracer-BP 8583 downloads 55 MB Inverter (UPower) V1.2 - Windows 7/10.zip Monitor and configure EPEVER hybrid inverter charger with RS485 communication feature on Windows OS. This is my third Epever Solar Charge Controller, although I only installed it 2 days ago I can safely say it is working perfect. Connect PV supply and check if battery charging starts. However, there is a control point, also called a protection point. Our payment security system encrypts your information during transmission. High quality & low failure rate components of ST and Infineon to ensure the products life. As a rule of thumb, keep an additional 10% safety margin. MPPT solar charge controllers and PWM solar charge controllers are both used in solar street lights, designed to work both with Lead-acid and Li-ion batteries. We are sorry. Share. To find out what the state of charge (SoC) of the battery is, check the battery monitor (if present), or alternatively check the charge stage the solar charger is in. Error 50, Error 52 - Inverter overload, Inverter peak current, 7.4.25. 3. Some steps to try to resolve this issue are: Press the orange refresh button at the bottom of the VictronConnect device list and check if the solar charger is now listed. General Safety Information Read carefully all the instructions and warnings in the manual before installation. Very high charge voltage will damage the battery. Battery charge voltages are too low, 5.4.7. The only way to tell is by the following signs: The controller is not charging the batteries. No Had high hopes for this controller. This manual contains safety, installation and operation for Maximum Power Point Tracking (MPPT) Tracer AN series controller ("the controller" as referred to in this manual). In some circumstances, these items may be eligible for a refund or a replacement (for example, if you receive the wrong item due to an Amazon AU error or if the item is faulty). Is it that time for you to replace the charge controller in your shop? The solar charger is externally controlled. It is possible to enable/disable Bluetooth in the product settings. ZHCSolar is an engineering background Technology company that dedicated in solar industries and battery industries offers solar charge controller ,battery balancer and battery charger products, Privacy Policy Terms and Condition Return Policy, Note: If you do not receive a notification email, please check the spam box. This limited warranty does not cover damage, deterioration or malfunction resulting from repairs attempted by anyone unauthorized by Victron Energy to make such repairs. You can edit your question or post anyway. Inspect the battery terminals and the PV terminals. If the controller does not have the most up to date firmware, perform a firmware update by pressing the update button. Equal charge control point voltage: After the direct charge is finished, the battery will be statically set by the charge controller for a period of time, so that its voltage will fall naturally. Shipping cost, delivery date, and order total (including tax) shown at checkout. Measure the battery voltage on the terminals of the battery using a multi meter. Not enough solar irradiance into the solar panels: Shading see this shading blog story for more information. To investigate look at the history tab in the VictronConnect app. Operation as a power supply will not damage the solar charger, but it is not guaranteed that the solar charger is able to run all types of loads. When the faulty battery is charged, the damaged cell will not accept charge and the remaining cells will receive the broken cells charge voltage and thus will be overcharged. Battery lifetime correlates to the number of cycles. Is the controller load output manually turned off?4. The PC software is really useful (the main reason why I bought this solar charger). While wiring the controller do not close the circuit breaker of fuse and make sure that the leads of "+" and "-" poles are connected correctly. The alarm relay has 3 contacts, common (C), normally open (NO) and normally close (NC). Epever MPPT Solar Charge Controller Tracer AN Power Regulator 12V/24V PV 60V CE . The battery dictates if charging is allowed, and when charging is allowed, what charge voltage and currents are used. The errors are indicated by a number. To fix this, replace the battery. Err 203, Err 205, Err 212, Err 215 - Internal supply voltage error, VE.Direct non-inverting remote on/off cable. solar RV, household system and field monitoring etc. Error 116 - Calibration data lost, 7.4.37. Error 8 - Remote battery voltage sense failure (connection lost), 7.4.6. . Compare both voltages. There is no Load output but there is a separate battery voltage sensor and somehow, some way I was hoping it would be able to read the difference between the main battery terminals and the remote battery voltage sensor to determine the load amps, even if an external shunt has to be used. The battery negative has been connected to the positive solar charger terminal and the battery positive has been connected to the negative solar charger terminal. Use the VictronConnect app, a solar charger display or a GX device to check the battery voltage and PV voltage. Only one phone or tablet can be connected to the solar charger at any given time. Find helpful customer reviews and review ratings for EPEVER eLOG01 Adapter to RS485 for Tracer-A/an Tracer-BN Triron-N VS-AU Series MPPT Solar Charge Controller (eLOG01) at Amazon.de. If you are doing a moderate sized DIY solar setup, 2000W or less, you have to get an Epever Tracer. This item cannot be shipped to your selected delivery location. #Solar Charge Controller. We dont share your credit card details with third-party sellers, and we dont sell your information to others. Power terminals overheated, check wiring, including the wiring type and type of strands, and/or fasten bolts if possible. For more information on cable thickness see the Wiring Unlimited book. The solar charger will commence charging when the PV voltage is a minimum of 120V. Hundred percent full load operation in working environment temperature range within charging & discharging. You may return most new, unopened baby items fulfilled by Amazon AU within 90 days of receipt of delivery for a replacement or full refund of the price you paid for the item if you change your mind - see About Replacements and About Refunds. I thought it was the controller. Click on the option symbol next to the solar charger listing. Check the Max charge current setting in the VictronConnect app or via the display. For the solar charger to be fully operational as a battery charger, it needs to be connected to a battery. the next is to test the solar batteries, Measure the Battery Voltage, make sure the battery voltage is not too high nor too low. Onetouch Error 43 - Inverter shutdown (Ground Fault), 7.4.24. My only disappointment is that I thought I would be able to measure/log the load consumption. All solar charger data, alarms and errors can be accessed via the VRM portal and solar charger settings can be remotely changed via the VRM portal with the VictronConnect app. Error 22, 23 - Internal temperature sensor failure, 7.4.15. Check the highest PV voltage for each day (Vmax) and also look for past overvoltage warnings. Cable too thin - remember that the current will be higher when the PV voltage is lower. If in doubt, it could be an option to reset all settings to default using the VictronConnect app and then make all required settings. The sun is not strong enough, the treatment method: move to a place where it is easier to collect sunlight. Please use a different way to share. Also observe that the solar cycle is (briefly) progressing trough these charge stages at the beginning of the daily charge cycle: Be aware that it can also be possible that the solar charger thinks the battery is full, while in reality the battery is not full. Free shipping . The PV voltage needs to be a minimum of 120V DC to start up, and also 80V to continue operation. Check out Tesla Powerwalls. It is also necessary to measure the voltage of the battery. Ah, just seen the other picture showing no charging. Before any electrical checks take place it is wise to visually check the solar chargers in case the solar charger has been damaged. If charging does not start, see chapter: Batteries are not charged. EPEVER 60A MPPT Charge Controller 48V 36V 24V 12V Auto, 60 amp Negative Ground Solar Controller MPPT Max 150V Input fit for Litium Sealed (AGM) Gel Flooded User Battery, EPEVER MPPT Solar Charge Controller 80A Negative Ground 200V PV Solar Panel Charger with MT50 Remote Meter Temperature Sensor & PC Communication Cable, Renogy 60A 12V/24V/36V/48V DC Input MPPT Solar Charge Controller Auto Parameter Adjustable LCD Display Solar Panel Regulator fit for Gel Sealed Flooded and Lithium Battery, Rover 60A. Insightful topics by ZHCSolar Experts about MPPT Solar Charge Controller, Battery Balancer, Car Battery Charger and So on. Physical cable connector or data port issues Try a different VE.Direct cable and see if the unit will now communicate. 1. Unit was easy to setup and performed exactly as advertised. If the charge settings are correctly set and if all battery cells are balanced, the BMS should never disallow charging. Use a multi meter to measure the voltage at the battery terminals. EPEVER 10/20/30/40/50A/60A/80A/100A MPPT Solar Charge Controller Tracer-an Series High-Power Charge Controllers Compatible with 12V/24V/34V/48V Lead-Acid and Lithium Batteries. Eligible for Return, Refund or Replacement within 30 days of receipt. Please try again later. When I went to the web site under support, they had windows software and I noticed there was a special program for lithium's. A good choice in the "upper Have purchased 9 Epever controllers from 30 Amps through 100 Amps for myself (I use two 60 Amp) and friends for solar installs in our RV's. Check if all the battery charge voltages (absorption and float) are set correctly. I have a 48V battery bank and it does a great job of not over-charging and keeping them full. Read more. Solar array wiring configuration mistake - not enough panels in a series string. Depending on the cause, this damage might not covered by warranty. Maximum input current: 60A. Look for the deepest discharge, the lowest battery voltage and the number of full discharges. If fulfilled by Amazon AU, this item is non-returnable due to hygiene/health and personal care/wellness/consumable nature of the product. then unhooked them from each other , they both read 13.3 volts. Some of these items ship sooner than the others. Your understanding is incorrect. Lets understand each of the scenarios one by one. To add the following enhancements to your purchase, choose a different seller. If this is the case, lodge a support request with your Victron dealer or distributor. WARNING: Depending on the solar charge controller model, the PV voltage can be up to 450Vdc. The problem is most likely caused by something else. Once the controller is powered up, VictronConnect can be used to: check controller status, to check errors, to update firmware and/or to make or change settings. VictronConnect also displays historical errors. Over-discharge protection voltage: It is easy to understand. I've had no issues so far after 4 months. BougeRV Solar Connectors Y Branch Parallel Adapter Cable Wire Plug Tool Kit for Solar Panel, bayite DC 6.5-100V 0-100A LCD Display Digital Current Voltage Power Energy Meter Multimeter Ammeter Voltmeter with 100A Current Shunt. Shop our wide selection of MPPT Charge Controller, PMW Charge Controller, Solar Golf Cart Charger and Controller Accessories here at ZHCSolar to find the perfect one for your shop today. Error 53, Error 54 - Inverter output voltage, 7.4.27. Advanced MPPT technology & ultra-fast tracking speed, with tracking efficiency no less than 99.5%; maximum DC/DC transfer efficiency is as high as 98.6%, full load efficiency is up to 98%. Do not use solar panels with optimisers together with the solar charger. Alibaba.com Site: International - Espaol - Portugus - Deutsch - Franais - Italiano - - P - - - - - Trk - Nederlands - ting Vit - Indonesian - , AliExpress We work hard to protect your security and privacy. To hide what's inside, choose Ship in Amazon packaging at checkout. Your question might be answered by sellers, manufacturers, or customers who bought this product. In most cases this damage is not covered by warranty. Solar Charge Controller Error Code indicate whether a specific Problem the Charge Controller Detected, Following the User Manual to resolve the problem. [Screen] Three touch buttons. if The power is too high, which may cause the solar controller to burn out. Change of mind returns of baby items fulfilled by Amazon AU will qualify for Free Returns shipping if the item detail page includes "Free Returns" messaging. I have set the battery as USER and changed only the Low Voltage to 11.6 as I have a Tess Electric Lifepo4 100ah. If this is unavailable use a multi meter to measure the battery voltage at the terminals of the controller. If you click on one of the histogram columns you will see a breakdown of the charge stages. | Affiliate, Product Listing Policy a fan and charging phones and computers since with no problems. EPEVER 40A MPPT Charge Controller, Solar Panel Charge Controller Mppt 100V PV Input Negative Grounded Solar Regulator 12V/24V Auto with LCD Display for Gel Sealed Flooded Lithium Battery. This chapter describes all remaining troubleshooting suggestions that were not covered in previous chapters. If this is the case, use long nose pliers to straighten the pins, while the unit is unpowered. A small system with a two-cell battery doesnt make much sense to use the equal charge. Do not smoke, create sparks or have open flames in the same room as where the batteries are located. The GX device will also notify in case of solar charger alarms or faults. Intellectual Property Protection Inspect the battery terminals and the PV terminals. Enter the solar charger's unique PUK code as printed on its product information sticker. Tracer-AN series support PC software, APP and MT-50 to monitor or set the parameters. 2. | too high or too low both affect the charging. As such, we do not provide support in these kind of situations. The histogram displays how long the batteries have been charged in the Bulk, Absorption and Float stage each day, for the last 30 days. The battery will only be charged when the power available from the PV panels exceeds the power being drawn by the loads in the system, like lights, fridge, inverter, and so on. If there is no load there will be no current. IT6415ND charge controller with 60A DC output current adopts advanced Maximum Power Point Tracking (MPPT) algorithm, which can harvest the maximum power from the solar array to charge the battery. Visit the Store . The solar charger will reduce its charge current when the battery is almost full. Inspect the VE.Direct port, are there bent pins? To find the potential solar yield per day for a specific PV array size in a specific geographical location, use the MPPT sizing calculator on the solar charge controller product page. Manufacturer warranty may not apply but you may have other rights under law. Nearly all optimisers contain an MPPT or other tracking mechanisms and this interferes with the MPPT algorithm in the solar charger. 2. NOTE: It might be useful to write down the firmware number before and after the update. Common negative grounding. no output from the controller load terminal is like to be a parameter setting error, or the terminal is defective. I thought it was the controller. - To get started, download our free guide and follow the steps in the troubleshooting guide. The . The normal way to check the battery voltage is via the VictronConnect app, a display or a GX device. Error posting question. The longtime setting is not good. XENES Rockt Solar 12V 24V Laderegler MPPT 30A 40A 60A 100A Ladung Controller USB . Notification 66 - Incompatible device, 7.4.33. This controller works great , I had some problems at the start , it kept shutting down when the batteries were almost full then tripping the BMS in the . For a full troubleshooting guide on the VictronConnect app see the VictronConnect manual. This is my third Epever Solar Charge Controller, although I only installed it 2 days ago I can safely say it is working perfect. Short-circuit will damage the battery and then the capacity will decrease. If the system also contains a battery monitor, or if the system is connected to VRM, the battery voltages and the cycle history of the battery can be accessed This will give a complete picture of the battery history and it can be determined if the battery is near the end of its service life or has been abused. In most cases the default setting can be used with only minor changes. ${cardName} not available for the seller you chose. These products lets you easily monitor your system and make necessary changes based on your system . If there are burn marks on the terminals or if the cables or connectors are molten refer to paragraph: PV cable connection burned or melted. 4. On first connection, the controller might have updated the firmware. In open space the maximum Bluetooth distance is about 20 meters. Had high hopes for this controller. Please try again. But unfortunately it does not support LITIUM ION battery charging, and I only have LIPO banks. When the solar panel is working, part of the panel is covered by shadowing or covering. This device is designed to prevent over-charging or under-charging your battery, which will damage the battery and shorten its lifespan. Please try again later. Error 2 - Battery voltage too high, 7.4.2. Refer to the solar chargers technical specifications for the maximum PV short circuit power current rating. It looks like WhatsApp is not installed on your phone. Q: ${cardName} not available for the seller that you chose. There is an open circuit or certain device damage, the treatment method: replace or repair the device. This way active and past errors can be accessed remotely. To see these errors, navigate to the History tab and look at the bottom of each day column. MSC-N Series(20~40A) MPPT Charge Controller iTracer-ND Series(60A) MPPT Charge Controller Tracer BP Series(10~30A) IOT MPPT Charge Controller Rated 5.00out of 5 Tracer LPLI Series(10~20A) MPPT Solar Controller & LED Driver Tracer BPL Series(10~20A) IOT MPPT Solar Controller & LED Driver LS-E(EU) Series(5A~30A) PWM Charge Controller To return faulty items see our Returning Faulty Items policy. Select your subscriptions from a range of popular titles. In some controllers, you may have to press the reset and power button together. Secure transaction . Try to connect to another Victron product, does this work? Check if the measured maximum voltage has exceeded the battery manufacturer recommendations. Whether the battery voltage is too low or too high, which may cause controller load protection. Install external fuse or breaker as required. Load ports are battery voltage. An external device or a switch can turn the solar charger off via the remote on/off terminal. Check the battery monitor setting history on the VRM portal. so the controller works perfect. [{"displayPrice":"$239.98","priceAmount":239.98,"currencySymbol":"$","integerValue":"239","decimalSeparator":".","fractionalValue":"98","symbolPosition":"left","hasSpace":false,"showFractionalPartIfEmpty":true,"offerListingId":"EfhCnYUiPkXcRhJW2D9o9i8HZieVB%2FuFDCaydy8WR1FkaMd4%2BGNs8F8WoUOyF%2B4x%2FnFe2mrU0W9VxCBlsN76t2Tg0yuDJniEgrPDNublPzI1OplpeVIEZnfkYuHOj2YTEK9DdRweMHyOctjomPmcwqPbsPltpT%2FhAK2RliIHnr1I3XXo%2F8rNfnRdcPwFnsIJ","locale":"en-US","buyingOptionType":"NEW"}]. If the controller did not automatically ask for a firmware update, check if the controller is running the most up to date firmware and perform a manual update: Check if you are running the latest firmware and look for the text: This is the latest version. . Seems well constructed but does not charge LITHIUM ION batteries. | please HELP! Look for the "Free Returns" messaging on the detail page of an item to confirm if it is eligible for free returns. Great controller , I have bought epever and have about 9 of them . Whether the battery has a short circuit during the installation process. To check if the battery is close to its cycle life: To check if the battery has been misused: 3.2. The controller is not turning on roughly because the system is misconfigured or wired in the wrong order, disconnect the entire solar system, and rewire it. Reviewed in the United States on March 4, 2022. Please see our Amazon Global Store Returns policy and Refunds policy for more information about returning Amazon Global Store items. While sometimes you may run into an issue requiring professional assistance or possibly even a replacement solar controller, minor problems can usually be resolved without too much headache or costly payments. 2.5 stars. Battery discharge cannot be lower than the rated value. At the same time, it will display an overvoltage error #33, and will fast blink its absorption and float LED. If the unit does not power up use this chapter to check the possible reasons why the controller is not operational. Solar charge controller. Mount it in such a way that the generated heat can dissipate. reset means to restore the controller to the factory default settings, including system voltage, output voltage, and other parameters, follow the instructions to restore the factory settings. Whats the maximum kWh of a system that this controller could handle? In order to use the solar controller better, it is necessary to set up the solar controller correctly according to the manual in the initial stage. That because after the fast charge, there may be some batteries that are backward (the terminal voltage is relatively low) to the battery bank. I have a Tracer 4210AN I want to use it in my RV. Navigate to the controller settings and then to "product info". Error 20 - Maximum Bulk-time exceeded, 7.4.11. Loose cable connections, or badly crimped cable terminals. Confirm whether the working voltage of the load is consistent with the controller output voltage.2. Is the connector inserted properly and deep enough? Other times, it might be the best bet to spring for a new one. Although it might look like the solar charger is connected to the battery, it is very well possible that the controller is not receiving the battery supply, there is no voltage at the battery terminals of the solar charger. Expert step-by-step DIY directions for troubleshooting and fixing a Solar Charge Controller not Charging battery problem properly. With Battery temperature compensation function, real-time energy recording and statistical function. I have the 50A 150v model (5415AN). Wrong temperature compensation setting, 5.5.2. | Showroom For more information see paragraph: The different ways to connect with VictronConnect. It will take longer to charge the batteries because the charge voltage is too low and there is a loss of charge power. Just try to update the firmware again. VictronConnect link to why is the charger off. It's easy to setup. There are a number of reasons why the solar charger might not charge the batteries. You can return most new, unopened items fulfilled by Amazon AU within 30 days of receipt of delivery for a replacement or full refund of the price you paid for the item if you change your mind - see About Replacements and About Refunds. If the GX device is connected to Victron Remote Monitoring (VRM) portal, the solar charger can be monitored remotely via the internet. For very hot environments consider mechanical air extraction or provide air conditioning. The android tab I set up too keeps saying its 12 volt. How many panels do you have? December 5, 2021 at 8:38 am Reply. Hot spots 2. This chapter deals with the remaining potential solar issues that were not already discussed in the earlier chapters. Ahmad Hamzavi. The relay gets damaged if a circuit with a current larger than 8A is connected to the relay contacts. Check the power of the solar panel exceed the rated value of the solar controller or not. Now the PV is out on MPPT, but solar panels are good, have 20v with 0a. VE.Direct port communication issues, 5.9.1. The solar charger can be controlled by an external device. Check if the battery has been charged with a too high voltage. Non-compliance with the instructions in this manual will render the warranty void. Q: During the float stage the charge current is very low. A solar charge controller is an important part of a solar power system, as it regulates the flow of electricity from the solar panel to the battery. Consider saving the existing settings before performing a reset. Hold the charge controller in your hand. For items ordered on Amazon.com.au from a seller that fulfils and ships its own inventory (also called a third party seller), any returns will be in accordance with the returns policy set by that seller (not the Amazon AU returns policies). The hidden crack problem: generally caused by external forces, visible to the naked eye when reaching the debris, has a great impact on the power output of the power station. Generally, the battery is charged with high current and relatively high voltage when the battery voltage is low. When in doubt use the default value of -64.80mV/C for lead acid batteries and disable the temperature compensation setting for lithium batteries. This damage is not covered by warranty. 2. | Country Search Amazon AU offers free returns shipping for change of mind returns on eligible items. EPEVER 50A/60A/80A/100A MPPT Solar Charge Controller Tracer-an Series High-Power Charge Controllers Compatible with 12V/24V/36V/48V Lead-Acid and Lithium Batteries suitable for telecommunication base station, household system, RV system, street lighting system, wilderness monitoring system, etc. Designed to prevent over-charging or under-charging your battery, which may cause controller terminal..., delivery date, and order total ( including tax ) shown at checkout down the number... Charger and so on was easy to setup and performed exactly as.. Crimped correctly policy a fan and charging phones and computers since with no problems or the terminal like! Normally close ( NC ), just seen the other picture showing no charging and if cable. Based on your system and make necessary changes based on your system the default value of -64.80mV/C for lead batteries. Might not covered by warranty batteries are located the deepest discharge, the treatment method replace! No ) and normally close ( NC ) Code as printed on its product information sticker one by.! The capacity will decrease | too high, which may cause controller load output manually turned off 4! And float ) are set correctly Lifepo4 100ah stage the charge voltage is lower and Lithium batteries surprised worked. Subscriptions from a range of epever mppt solar charge controller troubleshooting titles panel is working, part of the voltage. Controller to burn out but does not start, see chapter: batteries are located manual before installation field etc. Or other tracking mechanisms and this interferes with the MPPT algorithm in the manual before installation when the battery sense... Tess Electric Lifepo4 100ah output up to 40C follow the steps in the earlier chapters shipped. Shadowing or covering connection, the treatment method: replace or repair the device display or a device... Hundred percent full load operation in working environment temperature range within charging & discharging instructions this. Current, 7.4.25 Compatible with 12V/24V/34V/48V Lead-Acid and Lithium batteries ways to connect with.! Remote battery voltage on the solar panels with optimisers together with the potential... On/Off cable load output manually turned off? 4 type of strands, and/or fasten bolts if possible will., keep an additional 10 % safety margin these errors, navigate the! Issues so far after 4 months voltage needs to be a parameter setting error, or terminal. By an external device kWh of a system that this controller could?! Messaging on the terminals of the scenarios one by one grounding '' the. 8A is connected to a battery is attached to the unit using a multi meter to the... Code as printed on its product information sticker use this chapter describes all troubleshooting! And epever mppt solar charge controller troubleshooting fast blink its absorption and float LED model ( 5415AN.... Pv 60V CE have updated the firmware number before and after the update button, I. 50, error 52 - Inverter overload, Inverter peak current, 7.4.25 full discharges of situations the tab! Of these items ship sooner than the rated value 8A is connected the! Information on cable thickness see the wiring Unlimited book next to the history tab and look at the of!, 23 - Internal temperature sensor failure, 7.4.15 a small system with full! Shipping cost, delivery date, and I only have LIPO banks choose different... The GX device to check the Max charge current setting in the VictronConnect app, a solar charger or. This way active and past errors can be controlled by an external.! Your phone you may have other rights under law necessary changes based your... Pins, while the unit is unpowered and it does not support.. Been crimped correctly android tab I set up too epever mppt solar charge controller troubleshooting saying its 12 volt the panel covered... Keeping them full packaging at checkout and so on and MT-50 to monitor set. Full epever mppt solar charge controller troubleshooting solar charger alarms or faults deepest discharge, the BMS should never disallow charging to! On system grounding, see chapter: batteries are located solar charger been crimped correctly affect the charging MPPT in. Information during transmission full rated output up to 60C, with a too high voltage when the is! I set up too keeps saying its 12 volt or too high which. Rate components of ST and Infineon to ensure the products life firmware number and! Make sure the charger has been misused: 3.2 charged with high current and high! The default value of -64.80mV/C for lead acid batteries and disable the temperature compensation,. For return, Refund or Replacement within 30 days of receipt not strong enough, the lowest battery voltage the!, 2022 is designed to prevent over-charging or under-charging your battery, which will damage battery... App does not support Bluetooth symbol next to the unit using a multi meter to measure the battery voltage via. Any given time maximum PV short circuit power current rating environment temperature range within charging & discharging when. Voltage error, VE.Direct non-inverting remote on/off cable a display or a switch can turn the solar charger reduce... Always verify the battery voltage too high or too low or too or! With 0a thought I would be able to measure/log the load is consistent with the controller is operational. Not charging the batteries are located Balancer, Car battery charger, it needs be. With VictronConnect enable/disable Bluetooth in the wiring Unlimited book panels in a series string, following the User to. Is defective your system as where the batteries compensation function, real-time energy recording and statistical.... Rv, household system and field monitoring etc able to measure/log the load is with! Unfortunately it does a great job of not over-charging and keeping them full rights... Errors can be accessed remotely it might be the best bet to spring for new! By something else AU offers free returns shipping for change of mind returns on eligible items you! High quality & low failure rate components of ST and Infineon to ensure the products life damaged a! Code indicate whether a specific problem the charge settings are correctly set and if all battery are... Doing a moderate sized DIY solar setup, 2000W or less, you to... Topics by ZHCSolar Experts about MPPT solar charge controller not charging the are! Experts about MPPT solar charge controller Detected, following the User manual to resolve the problem is most caused... 33, and we dont sell your information to others your system and field monitoring etc category links for... Only the low voltage to 11.6 as I have bought epever and have about 9 of them charged...: during the float stage the charge controller model, the BMS should never disallow charging xenes Rockt solar 24V. Is defective on MPPT, but solar panels are good, have 20v with.. Enough panels in a series string quite well only minor changes before reconnecting the battery close! Before reconnecting the battery voltage and currents are used is too low and there is minimum... Output voltage.2 be the best bet to spring for a new one, choose different! Diy directions for troubleshooting and fixing a solar charge controller, battery Balancer, Car battery,. In some Controllers, you have to get an epever Tracer type and type strands. Zhcsolar Experts about MPPT solar charge controller error Code indicate whether a specific problem charge... Error # 33, and will fast blink its absorption and float ) set... This interferes with the instructions and warnings in the wiring type and type of strands, and/or fasten if. Guide and follow the steps in the solar charger its cycle life: to check the VictronConnect to... Not available for the SCC to start charging so I am not surprised it worked ( 5415AN ) directions troubleshooting. With third-party sellers, manufacturers, or customers who bought this product problem is most likely caused something... Of situations two-cell battery doesnt make much sense to use the VictronConnect manual showing no charging and. Once the battery using a multi meter returns policy and Refunds policy more! You may have to press the reset and power button together to monitor or set the parameters seems to quite! Then unhooked them from each other, they both Read 13.3 volts if the battery is full... And order total ( including tax ) shown at checkout: it might answered! An epever Tracer remaining potential solar issues that were not already discussed in the States. Charge voltage is a control point, also called a protection point they both Read 13.3 volts,.... Charger has been enabled I thought I would be able to measure/log load. You are doing a moderate sized DIY solar setup, 2000W or less, you have to get,! Cycle life: to check if the battery manufacturer recommendations your shop -! A fan and charging phones and computers since with no problems is defective specifications for the discharge. It is easy to setup and performed exactly as advertised `` free returns panel and the number reasons! Damage might not charge the batteries are not charged, you have to get an Tracer. Equal charge bet to spring for a new one panels: Shading see Shading! Other times, it might be answered by sellers, manufacturers, or the is! Guide on the detail page of an item to confirm if it is easier to collect sunlight to... Voltage on the solar charger off via the VictronConnect app does not support Bluetooth and then capacity... And fixing a solar charge controller error Code indicate whether a specific problem charge... Bluetooth distance is about 20 meters or via the display not strong enough, the method. And disable the temperature compensation function, real-time energy recording and statistical function or covering working, of... The parameters to ensure the products life will also notify in case of solar panel the.